Industries

If you run to these standards, we cover you.

FoxIQ works across the whole control system: the alarms operators see, the logic behind them, the safety systems that trip the plant, and the documents that are supposed to describe all of it. Our work is built on the standards themselves, so it applies to every industry that operates by them.

Refining and petrochemical

Decades of modifications, alarms added and never removed, and logic that no longer matches its documents.

Alarm management

PSM-grade KPI audit, flood cascade maps and suppression rules ready for MOC, with SIS trips correlated to their precursor alarms.

Control and safety logic

Interlocks verified against the cause-and-effect matrix, and the configured controller compared with the narratives it is supposed to follow.

Field and documentation

Narratives rebuilt from the running code, loop folders generated from the tag register, and turnaround commissioning support.

Offshore production

Small crews, slugging and flow instability, and safety systems that must work first time with no one on hand to diagnose.

Alarm management

Oscillating tags identified as one phenomenon with one cause, frozen and failed instruments surfaced. Proven on real offshore well data.

Control and safety logic

Well and topsides shutdown logic checked against the cause-and-effect matrix, including voting and bypass behaviour.

Field and documentation

Engineers who work offshore commissioning rotations, and documentation built to hand over to the platform crew.

LNG and gas processing

Short time to consequence, tightly coupled trains, and startup behaviour nothing like steady state.

Alarm management

Flood analysis under short response windows, with KPIs split by startup, steady state and shutdown.

Control and safety logic

Trip sequences verified scan by scan, so rung order cannot defeat the shutdown design.

Field and documentation

Commissioning support through startup, when alarm and trip behaviour is least understood.

Pipeline SCADA

Controllers watching long lines across many stations, under federal control-room management rules.

Alarm management

API RP 1167 KPIs per controller and console workload modelling, documented for control-room management review.

Control and safety logic

Station PLC logic reviewed for permissives and shutdowns that do not match the documented design.

Field and documentation

Station documentation brought back in line with what is actually installed.

Power generation

Unit trips and start-up sequences flood operators at exactly the wrong moment.

Alarm management

Trip and start-up alarm sequence audits, with precursor alarms ranked by how reliably they come before a trip.

Control and safety logic

Balance-of-plant PLC logic reviewed and standardized, with interlocks verified against the design.

Field and documentation

Control narratives and loop documentation rebuilt for outages and upgrades.

Pharmaceutical and biotech

Batch phases change alarm behaviour, and every analysis has to survive a data-integrity audit.

Alarm management

Phase-aware batch KPIs with a hashed analysis audit trail.

Control and safety logic

Configured-versus-documented comparison, so validated documents match the code that actually runs.

Field and documentation

Documentation packages structured for validation review.

Datacenters and critical facilities

Building and electrical systems that alarm on everything, with critical events buried among informational ones.

Alarm management

BMS and EPMS rationalization and cascade analysis of electrical and cooling events.

Control and safety logic

Transfer, load-shed and cooling control logic reviewed against the sequence of operations.

Field and documentation

Sequence-of-operations documents rebuilt from the code, and commissioning support.

Also covered

  • Chemicals and specialty chemicals
  • Fertilizers and ammonia
  • Midstream and gas storage
  • Water and wastewater
  • Mining and minerals
  • Pulp and paper
  • Food and beverage
  • District energy and utilities

One team across the whole control system

Most firms cover one layer and hand you to someone else for the next. We cover all five, and we check each one against the others.

FoxALM

Alarm management

  • ISA-18.2 KPI audit and grading
  • Floods traced to their first alarm
  • Suppression rules in your DCS’s import format
  • PID retuning for chattering loops
  • Improvement verified after implementation
PLC review

Control logic

  • Line-by-line code review
  • Configured versus documented
  • Standardization onto documented libraries
  • Logic minimized and proven equivalent
Verification

Cause and effect

  • Interlocks checked against the matrix
  • Masked causes and redundant cells
  • Trips that a start command can override
  • Scan-by-scan correctness
Functional safety

Safety instrumented systems

  • SIS logic checked against the C&E and safety requirements
  • Voting architectures reviewed for common-cause failure
  • Bypass and override logic reviewed
  • Safety alarms tied to their trips
Red Fox Automation

Documentation and field

  • Control narratives written from the code
  • Instrument loop folders from your tag register
  • Loop checks and commissioning support
  • Integration and panel fabrication

The standards we work to

Alarm management

  • ISA-18.2-2016
  • IEC 62682:2022
  • EEMUA 191 (2024)
  • API RP 1167

Safety instrumented systems

  • IEC 61511
  • IEC 61508
  • ISA-84

Control logic and documentation

  • IEC 61131-3
  • ISA-5.1

Regulatory

  • OSHA PSM 1910.119
  • 49 CFR 192 / 195
  • 21 CFR Part 11
  • NERC

Engineering you can hold to account

What you get when the people doing the analysis have also stood in front of the panel.

Tell us what you run and which standards you answer to. An engineer replies the same day.

Talk to an engineer