Offshore oil wells: FoxALM on real field data

Sensor data from offshore oil wells, one sample per second, with every undesirable event labelled by experts. We ran the full FoxALM pipeline across all ten event classes. Every check we wrote from those labels before the first run passed.

42 / 42checks derived from the expert labels, all passed
30end-to-end pipeline runs, one version
10labelled event classes, real wells only
3defects surfaced by real data, fixed before publishing

The wells

Sensor data from offshore oil wells operated by a major oil company off the coast of Brazil, recorded at one sample per second, with undesirable events labelled by experts: from normal operation to severe slugging, flow instability and spurious safety-valve closure. We took one well record per event class, chosen by a fixed rule written down before selection, and used real well data only.

The records carry no alarm log, so alarms were generated from each sensor’s normal behaviour. Every event class was run three ways: raw thresholds, an ISA-18.2 on-delay filter, and a deadband. Ten classes, three variants, thirty runs, all on a single pipeline version.

What we checked

Raw thresholds bury the operator in chattering alarms. The oscillation analysis flags every fault-affected sensor with one coherent frequency: one phenomenon to fix, not hundreds of alarms to acknowledge. Measured on the real-well instances of both dynamics classes.

What real data taught us

Real field data at one sample per second surfaced three defects in FoxALM that the simulated benchmark had not: a limit in how finely oscillation periods were measured, a fault in the KPI trend chart, and a crash on heavily rationalized alarm sets. All three were fixed before any result was published.

We also corrected our own test design in the open. We wrote 44 checks; two asked for fault detection on the fault-free well, which has no fault to detect. They were removed before publication and the count stated as 42.

What this did not test

The oscillation check confirms detection, not specificity: on the fault-free well, most sensors were also flagged as oscillating. Several analyses ran on every instance but were not checked against the labels here; their correctness rests on their written specifications and our standing conformance checks.

We state limits because a claim you can’t check is a claim you shouldn’t rely on.

Reproducible

Every input file is pinned by SHA-256. Each of the thirty runs has a committed manifest, all from a single auditable pipeline version.

The same analysis, on your unit. Send us three to twelve months of alarm history.

Request an assessment